RAINFORD | Outdoor Infrastructure Solutions

RAINFORD Titan™ Cabin: Secure Outdoor Infrastructure for Defence, Mobile & Rail

Critical infrastructure requires dependable equipment protection, whether supporting defence communications, mobile network deployments or rail signalling systems. The RAINFORD Titan™ Cabin range provides a secure, climate-managed outdoor equipment environment, combining robust construction, configurable cooling and practical installation features.

RAINFORD Titan outdoor equipment cabin
19-Point Locking High-security access system
70mm Insulation Double-skinned insulated panels
AC/DC Ventilation Battery-backed interim airflow
Modular Design Multiple cabin and cooling options
Technical Insights

Why Outdoor Equipment Cabins Matter for Critical Infrastructure

Communications and signalling equipment often needs to operate at remote or exposed sites, where physical security, weather protection and thermal management are important considerations.

Unlike a conventional equipment cabinet, an outdoor equipment cabin provides a dedicated environment for housing larger infrastructure installations, associated power systems and supporting equipment.

The RAINFORD Titan™ Cabin range uses riveted and bolted modular panels, a stainless steel outer skin, galvanised steel inner skin and 70mm polystyrene insulation. The design is intended to provide a secure, climate-managed environment for infrastructure across multiple sectors.

Industry Applications

One Cabin Platform. Three Critical Sectors.

From defence communications to mobile network infrastructure and rail signalling, the Titan™ Cabin offers a configurable approach to outdoor equipment protection.

01 / DEFENCE

Defence Communications Infrastructure

Defence communications projects may require secure, protected equipment environments at operational sites and remote installations. The Titan™ Cabin offers robust construction, high-security locking and configurable ventilation and cooling.

Its modular design provides flexibility when planning equipment layouts, power distribution, cable entry and maintenance access.

02 / MOBILE NETWORKS

Mobile Network Equipment Housing

Mobile network infrastructure relies on protected equipment environments for radio access, transmission, power and associated network systems.

The Titan™ Cabin supports outdoor telecommunications installations with secure access, cable ingress provisions, insulated construction and configurable cooling. Its modular design enables equipment accommodation to be considered around site footprint and capacity.

03 / RAIL

Rail Signalling & Trackside Infrastructure

Rail infrastructure projects can require secure outdoor accommodation for signalling, communications, power and associated electronic equipment.

The Titan™ Cabin's modular construction, insulated panels, cable ingress features and ventilation options make it a potential solution for rail equipment housing, subject to project-specific standards and site requirements.

Product Engineering

Designed for Security, Protection and Performance

The Titan™ Cabin brings together structural protection, access security and equipment environmental management.

Double-Skinned Steel Construction

1.5mm 1.4003 stainless steel outer skin with a 1.2mm galvanised steel inner skin, assembled using riveted and bolted modular panels.

70mm Insulated Panels

Polystyrene insulation helps provide a controlled internal equipment environment when combined with appropriately specified ventilation or air conditioning.

19-Point Security Locking

An outward-opening single door with a 19-point locking system supports secure access to housed equipment.

Dual AC/DC Forced Ventilation

Standard ventilation includes one AC fan and one DC fan, with variable speed control and battery-backed interim airflow during power outages.

Flexible Cable Entry

Roxtec-compatible blanked gland plate apertures and a base cable ingress duct support the routing of infrastructure cabling.

Installation & Floor Protection

Base-mounted crane lifting points, a galvanised rodent-protection layer and marine-grade plywood flooring with anti-static ESD vinyl finish.

Operational Resilience

Managing Equipment Conditions During Power Interruptions

Outdoor equipment environments require suitable ventilation and cooling to support installed electronics.

The standard Titan™ Cabin ventilation arrangement incorporates one AC fan and one DC fan. During a power outage, the DC fan can operate on battery backup to provide interim ventilation.

This battery-backed operating mode does not provide the full ventilation duty. Where equipment heat loads require additional cooling, optional 6kW or 9kW air conditioning can be specified.

Cooling requirements should be assessed against the equipment configuration, heat output and expected site conditions.

RAINFORD Titan Cabin construction and external details

Planning an Outdoor Infrastructure Project?

Whether your project involves defence communications, mobile network expansion or rail infrastructure, our sales team can help you explore suitable Titan™ Cabin sizes, cooling options and configurations.

RAINFORD Titan™ Cabin

Explore the Cabin Range

A closer look at the exterior, construction and configurations available within the Titan™ range.

Cabin Configurations

Multiple Sizes to Suit Your Installation

From space-restricted ground-level installations to larger outdoor equipment rooms, the Titan™ range provides several standard cabin formats.

Titan™ Micro Cabin

External: 2355 × 757 × 1457mm

Internal: 2080 × 599 × 1264mm

Compact configuration for ground-level installations with limited available space.

Titan™ Small Cabin

External: 2830 × 1800 × 1800mm

Internal: 2560 × 1640 × 1640mm

Suitable for outdoor installations requiring a dedicated equipment environment within a compact footprint.

Titan™ Medium Cabin

External: 2830 × 2710 × 2710mm

Internal: 2560 × 2540 × 2540mm

Provides increased internal space for larger equipment configurations and supporting infrastructure.

Additional depths, cooling options and Goose Grey or Moss Green finishes are available on request.

RAINFORD equipment cabins prepared for dispatch from the manufacturing facility
From Manufacturing to Deployment

Built for Critical Infrastructure. Prepared for Delivery.

RAINFORD's approach to equipment housing extends beyond the design of the cabin itself. From manufacturing and configuration through to preparation for dispatch, the focus is on supplying infrastructure solutions suited to the requirements of each project.

The Titan™ Cabin's modular construction, configurable dimensions and cooling options enable customers to specify equipment accommodation around the demands of defence, mobile network and rail infrastructure.

Whether you are planning a single installation or a wider infrastructure programme, our team can discuss technical requirements, available configurations and delivery needs before quotation.

Defence & Critical Infrastructure

Frequently Asked Questions

Key considerations when specifying outdoor equipment cabins for defence communications and secure infrastructure.

How can the RAINFORD Titan™ Cabin support defence communications infrastructure?

The Titan™ Cabin provides secure, insulated and climate-managed outdoor equipment housing for defence communications applications. Its modular construction, 19-point locking system and configurable ventilation and cooling make it suitable for consideration where protected equipment accommodation is required. Project-specific defence requirements should be confirmed during specification.

What security features are available for defence equipment installations?

The cabin incorporates an outward-opening door with a 19-point locking system, double-skinned steel construction and a protected cable ingress arrangement. Additional site security requirements should be reviewed as part of the overall installation design.

Can the Titan™ Cabin accommodate different defence communications equipment layouts?

The Titan™ range includes Micro, Small and Medium configurations, with additional depths and cooling options available on request. Equipment dimensions, access clearances, power requirements and thermal loads should be reviewed before selecting the final cabin configuration.

How is ventilation maintained during a power interruption?

The standard ventilation system includes an AC fan and a DC fan. The DC fan can operate on battery backup to provide interim ventilation during a power outage. This does not provide the full ventilation duty, so equipment heat loads and backup arrangements must be considered when planning critical installations.

Can RAINFORD Titan™ Cabins be specified for individual defence projects?

Yes. The modular range offers a choice of cabin dimensions, ventilation or air-conditioning arrangements and colour finishes. The Telenco UK sales team can discuss available configurations against the project's technical, operational and installation requirements.

How do I request a quotation for a defence infrastructure project?

Contact the Telenco UK sales team with the intended application, required equipment accommodation, site conditions, cooling requirements and expected delivery needs. Our team can help review the available Titan™ Cabin options and prepare a quotation.

RAINFORD | A Telenco Brand

Let's Discuss Your Infrastructure Requirements

From defence communications and mobile network installations to rail signalling infrastructure, the RAINFORD Titan™ Cabin range offers secure, configurable outdoor equipment housing.

Speak to our sales team about your project, required cabin dimensions, equipment layout and cooling needs. We can help you explore the available configurations and request a quotation.